- Quality of the measurement data is low.
- Origin of the data is Vue Audiotechnik.
- Format of the data is a GLL file .
-
Sensitivity:
- Company: 98 dB
- Measured: 99.0 dB (avg. 300Hz-3kHz for 2.83V estimated at 1m).
- Measured: 79.0 dB computed at the measurement distance (10.0m) over the same frequency range.
- -3dB (resp. -6db) point v.s. reference is at 118.0Hz (resp. 95.0Hz).
- Reference level is normalised to 0.1dB computed over the frequency range [300.0Hz, 5000.0Hz].
- Frequency deviation is 4.8dB over the same frequency range.
- Tonality (Preference) Score
- Tonality (Preference) Score is 1.29
and would be 4.9 with a
perfect subwoofer.
- Details: NBD: ON 0.754, LW 0.776, SP 0.766, PIR 0.761; SM: SP0.793, PIR0.592; LFQ 3.26, LFX 100Hz
- Tonality (Preference) Score is 3.04
with an EQ and would be 6.29 with a
perfect subwoofer and the same EQ.
- Details: NBD: ON 0.586, LW 0.6, SP 0.598, PIR 0.584; SM: SP0.882, PIR0.785; LFQ 2.874, LFX 82Hz
- Tonality (Preference) Score is 1.29
and would be 4.9 with a
perfect subwoofer.